TempSafe® EcoShield

TempSafe® EcoShield™ is a sustainable, pre-qualified thermal cooler built for performance and responsibility.

Designed for last-mile residential prescription delivery, each system maintains temperature control through both summer and winter conditions—keeping critical therapies protected while reducing environmental impact.

  • Curbside-recyclable* exterior
  • Made from recycled corrugated with OCC-E Certified, repulpable cellulose insulation
  • Free from chemical additives
  • Validated through ISTA 7E testing for over 48 hours
  • Prequalified for both summer and winter applications

 

*may not be recyclable in your area, please check local guidelines

TempSafe® EcoShield

TempSafe® EcoShield™ is a sustainable, pre-qualified thermal cooler built for performance and responsibility.

Designed for last-mile residential prescription delivery, each system maintains temperature control through both summer and winter conditions—keeping critical therapies protected while reducing environmental impact.

  • Curbside-recyclable* exterior
  • Made from recycled corrugated with OCC-E Certified, repulpable cellulose insulation
  • Free from chemical additives
  • Validated through ISTA 7E testing for over 48 hours
  • Prequalified for both summer and winter applications

*may not be recyclable in your area, please check local guidelines
Part # Temperature Range Payload Liters Payload Inches Payload Space (LxWxD) Min Duration
ES-XS-2R Refrigerated 2 130 9.0625 x 6.0625 x 2.375 36+
ES-XS-2CRT CRT 2 130 9.0625 x 6.0625 x 2.375 36+
ES-SM-5R Refrigerated 5 281 10.875 x 7.375 x 3.5 36+
ES-SM-5CRT CRT 5 281 10.875 x 7.375 x 3.5 36+
ES-MD-10R Refrigerated 10 603 12.625 x 8.3125 x 5.75 36+
ES-MD-10CRT CRT 10 603 12.625 x 8.3125 x 5.75 36+
ES-LG-15R Refrigerated 15 917 11.5 x 9.25 x 8.625 36+
ES-LG-15CRT CRT 15 917 11.5 x 9.25 x 8.625 36+
ES-XL-29R Refrigerated 29 1762 15.25 x 10.75 x 10.75 36+
ES-XL-29CRT CRT 29 1762 15.25 x 10.75 x 10.75 36+

Applications

  • Last-mile prescription and specialty pharma delivery
  • Home healthcare shipments
  • Diagnostics and clinical samples

Frequently Asked Questions (FAQs)​

Q. What does "Cold Chain" mean?

A. Cold Chain refers to the process or products involved in shipping temperature-sensitive items from origin to destination while maintaining a stable environment within the cooler. This prevents spoilage of food and maintains the stability and efficacy of life-altering medications.

Q. What are the most common temperature ranges for cold chain shipping?

A. The four conventional temperature ranges are:​

Frozen/Dry Ice (<-20°C)​ Refrigerated (2-8°C)​ Ambient/Room Temp (15-25°C)​ Cryogenic/Liquid Nitrogen Frozen (>-80°C)

Q. What is a temperature excursion?

A. Temperature excursion occurs when a product that must maintain a specific temperature range falls below or exceeds that range. For example, if a product required to stay between 2°C – 8°C falls below 2°C or rises above 8°C, it results in a temperature excursion.​

Q. Is dry ice better than frozen gel packs for shipping frozen products?

A. Many factors are used to determine when dry ice should be used over frozen gel packs. Dry ice is one of the more costly options but offers the best duration. It sublimates up to 10 pounds per day depending on the ambient temperature and turns into carbon dioxide. Be cautious of trapped gases when opening the cooler.

A. To maximize the life and duration of refrigerants, the recommended conditioning temperature is -20°C. Some companies freeze their refrigerants at -5 to -10°C, which is less effective. Depending on the validated solution, refrigerants may need to be benched at room temperature before being packed out to avoid flash freezing.
Q. What is a validated shipper and when should it be used?
A. Validated shippers are designed and tested to meet the temperature and duration requirements of a custom payload. They are tested against strict seasonal temperature profiles for repeatable results in environmental chambers, and are often used for life science, healthcare, and pharma applications requiring consistent results to protect product efficacy.​
Q. What does product stability mean?​
A. Product stability refers to the ability of some products to withstand temperature excursions for a specific duration. The stability is determined by the product manufacturer. For example, a vaccine that must stay between 2-8°C may remain stable up to 15°C for less than 8 hours. If the temperature falls below 2°C or rises above 8°C, the product is no longer safe to use.

Contact Us

Our experts create custom solutions to keep your temperature-controlled products safe and efficient during delivery. Contact us today to get started!

Sign in to Veritiv

Registered customers in the Northeast can now purchase on veritiv.com for delivery to CT, DE, MA, MD, ME, NH, NJ, NY, RI, VT, and Eastern PA. 

Need help signing in? Email eBusinessSupport@veritivcorp.com

Email Address

Password

Already a Customer and Need an
Online Account?

Outside the Northeast?

If your delivery state is not yet listed on the left, continue purchasing on commerce.veritivcorp.com

Login and ship other legacy brands.

Sign In

Registered customers in the Northeast can now purchase on veritiv.com for delivery to CT, DE, MA, MD, ME, NH, NJ, NY, RI, VT, and Eastern PA. 

Need help signing in? Email eBusinessSupport@veritivcorp.com

Email Address

Password

Already a Customer and Need an Online Account?

Outside the Northeast?

If your delivery state is not yet listed on the left, continue purchasing on commerce.veritivcorp.com

Login and ship other legacy brands.